Cable temperature of cables supplying solar inverters.

I don't understand why, for circuits supplying inverters, when you look at the cable temperature it only shows ambient temp and not what the cable temp would be under full load/capacity. Can this be added please?
Guest 11 days ago in Calculation 0 Gathering support

Collated Simulation Report

Could it be possible to select the reports wanted for export to PDF and then ProDesign includes them all into one documents with Titlepage and contents table and then the selected reports in order? I've received some electrical OM reports for revi...
Guest 6 months ago in Other 0 Gathering support

Definition between existing and proposed systems

Currently, the program is great for new systems but not so good when retro fitting or upgrading electrical supplies. A way to distinguish between existing and new items would be great, circuit charts could just show 'existing' for circuits already...
Charles Proctor 3 months ago in Other 0 Gathering support

Add installation method 47 for SWA cables.

Often SWA cables are installed below raised access floors within commercial office buildings especially for underfloor power tracks. It would be very useful to have this as an installation option rather than having to pick another method B and hav...
Guest about 2 months ago in Calculation 0 Gathering support

Changing Installation Method for an Armoured cable resets CPC configuration

When the Installation Method is changed the CPC configuration should be retained. The current functionality creates needless work.
Scott Dakin 5 months ago in Components 0 Gathering support

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!
Guest 4 months ago in Other 0 Gathering support

Add adjustable settings to custom reports

The adjustable device settings dont currently show in custom reports. It would be useful if it were possible to add them, aswell as the time delays from adjustable RCDs. Adjustable RCD settings should also be shown on the protective device setting...
Guest 5 months ago in Other 0 Gathering support

Split Metered/Load Distribution Board

Customers would like the option to label two halves of the board differently e.g. DB1L and DB1P (L for lighting, P for power) so that the two halves of the board have their own identity. It will also require the ability to select the number of way...
Ayee Jarecki 11 months ago in Components 2 Gathering support

Add adjustable device settings to Display Results

I'd like the tripping curve of MCBs and ACB or MCCB adjustable pickup values to be options in the Display Results interface. Our site team wants them written on the canvas so i'm having to type them all out by hand. Yes, I agree it's a bit daft as...
Scott Dakin 6 months ago in Other 0 Gathering support

Set adjustable device pickup values for multiple devices simultaneously

Having to setup dozens of identical devices one-at-a-time instead of being able to do them all at the same time wastes unbelievable amounts of time. It's even worse when you have to iterate all of them several times, losing days to do what should ...
Scott Dakin 6 months ago in Components 0 Gathering support