Add the option to be able to add custom cables to the cable database

Add an option to allow the use of cables greater than 300mm2 for multicore XLPE/SWA CU cables.
Guest 4 months ago in Manufacturer Data 0 Gathering support

415V/110V Supply for LV/LV Transformers

Add an option to take 415V single phase L-L supply from a board for the LV/LV transformers
Guest over 1 year ago in Components 0 Gathering support

Custom Reports

Customers would like to define the information they want instead of being dictated by us what appears on the standard reports. They also want their own company 'identity'. Allows customer to be more flexible in what they show on their reports. Con...
Ayee Jarecki over 1 year ago in Other 0 Gathering support

6.6kV rating applied to Merlin Gerin MV Ringmaster Range .

In Electricity North Wests area they have primary substation network operating at 6.6kV and a fault level of 250MVA. The Ringmaster range is rated to 21.9KA therefore compatible but it returns an error code for the Pscc exceeding fault capacity as...
Guest 4 months ago in Components 0 Gathering support

Definition between existing and proposed systems

Currently, the program is great for new systems but not so good when retro fitting or upgrading electrical supplies. A way to distinguish between existing and new items would be great, circuit charts could just show 'existing' for circuits already...
Charles Proctor 9 months ago in Other 0 Gathering support

Add devices from Protect to ProDesign

Add the devices from Protect into ProDesign so that I can correctly configure the source of supply. The list of available devices in ProDesign for LV and especially HV protection at source is rather limited.
Scott Dakin about 1 year ago in Calculation 0 Gathering support

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!
Guest 10 months ago in Other 0 Gathering support

Add adjustable settings to custom reports

The adjustable device settings dont currently show in custom reports. It would be useful if it were possible to add them, aswell as the time delays from adjustable RCDs. Adjustable RCD settings should also be shown on the protective device setting...
Guest 12 months ago in Other 0 Gathering support

Add adjustable device settings to Display Results

I'd like the tripping curve of MCBs and ACB or MCCB adjustable pickup values to be options in the Display Results interface. Our site team wants them written on the canvas so i'm having to type them all out by hand. Yes, I agree it's a bit daft as...
Scott Dakin about 1 year ago in Other 0 Gathering support

Set adjustable device pickup values for multiple devices simultaneously

Having to setup dozens of identical devices one-at-a-time instead of being able to do them all at the same time wastes unbelievable amounts of time. It's even worse when you have to iterate all of them several times, losing days to do what should ...