415V/110V Supply for LV/LV Transformers

Add an option to take 415V single phase L-L supply from a board for the LV/LV transformers
Guest about 1 year ago in Components Gathering support

Add adjustable settings to custom reports

The adjustable device settings dont currently show in custom reports. It would be useful if it were possible to add them, aswell as the time delays from adjustable RCDs. Adjustable RCD settings should also be shown on the protective device setting...
Guest 8 months ago in Other Gathering support

Add adjustable device settings to Display Results

I'd like the tripping curve of MCBs and ACB or MCCB adjustable pickup values to be options in the Display Results interface. Our site team wants them written on the canvas so i'm having to type them all out by hand. Yes, I agree it's a bit daft as...
Scott Dakin 9 months ago in Other Gathering support

Set adjustable device pickup values for multiple devices simultaneously

Having to setup dozens of identical devices one-at-a-time instead of being able to do them all at the same time wastes unbelievable amounts of time. It's even worse when you have to iterate all of them several times, losing days to do what should ...
Scott Dakin 9 months ago in Components Gathering support

Custom Reports

Customers would like to define the information they want instead of being dictated by us what appears on the standard reports. They also want their own company 'identity'. Allows customer to be more flexible in what they show on their reports. Con...
Ayee Jarecki about 1 year ago in Other Gathering support

Add installation method 47 for SWA cables.

Often SWA cables are installed below raised access floors within commercial office buildings especially for underfloor power tracks. It would be very useful to have this as an installation option rather than having to pick another method B and hav...
Guest 5 months ago in Calculation Gathering support

Provide global controls for annotation & display results

When I am configuring the parameters shown in the display results text boxes on the canvas and the style of the text I have to edit each one individually. I don't see any reason why this could not be handled with global controls to make them all f...
Scott Dakin 10 months ago in Other Gathering support

Add Starting Current to the Display Results interface for motors

Display Results for motors shows many useful parameter values, for some reason the motor starting current is missing for the motors interface. Seeing this value on the canvas would allow me to select an appropriate circuit protective device for an...
Scott Dakin 10 months ago in Calculation Gathering support

Save user configuration for much more content in ProDesign

While I can save my settings for a few items such as the Phase labels and canvas background colour there is a whole lot more that it could control so that i don't have to keep reinventing the wheel when i start a project
Scott Dakin 11 months ago in Other Gathering support

Copy & Paste functionality in ProDesign

Copy & Paste of submains does not copy and paste all of the details, it misses some out, such as the protective device. This creates work that should not exist
Scott Dakin 11 months ago in Other Gathering support