Trimble Electrical Designer

Add the option to be able to add custom cables to the cable database

Add an option to allow the use of cables greater than 300mm2 for multicore XLPE/SWA CU cables.
Guest 24 days ago in Manufacturer Data Gathering support

6.6kV rating applied to Merlin Gerin MV Ringmaster Range .

In Electricity North Wests area they have primary substation network operating at 6.6kV and a fault level of 250MVA. The Ringmaster range is rated to 21.9KA therefore compatible but it returns an error code for the Pscc exceeding fault capacity as...
Guest about 1 month ago in Components Gathering support

We cannot operate two generators with different ratings in parallel.

Construction & site engineers to use different rating generators in parallel to supply for temporary supply in site.
Guest 3 months ago in Calculation Gathering support

Cable temperature of cables supplying solar inverters.

I don't understand why, for circuits supplying inverters, when you look at the cable temperature it only shows ambient temp and not what the cable temp would be under full load/capacity. Can this be added please?
Guest 4 months ago in Calculation Gathering support

Add installation method 47 for SWA cables.

Often SWA cables are installed below raised access floors within commercial office buildings especially for underfloor power tracks. It would be very useful to have this as an installation option rather than having to pick another method B and hav...
Guest 5 months ago in Calculation Gathering support

optie toevoegen aan resultaten weergeven > waarden (bij instellingen kabel)

Max. lengte spanningsverl. NIET zichtbaar in het schema
Majd Samuel 6 months ago in Calculation Gathering support

Definition between existing and proposed systems

Currently, the program is great for new systems but not so good when retro fitting or upgrading electrical supplies. A way to distinguish between existing and new items would be great, circuit charts could just show 'existing' for circuits already...
Charles Proctor 6 months ago in Other Gathering support

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!
Guest 7 months ago in Other Gathering support

Changing Installation Method for an Armoured cable resets CPC configuration

When the Installation Method is changed the CPC configuration should be retained. The current functionality creates needless work.
Scott Dakin 8 months ago in Components Gathering support

Add adjustable settings to custom reports

The adjustable device settings dont currently show in custom reports. It would be useful if it were possible to add them, aswell as the time delays from adjustable RCDs. Adjustable RCD settings should also be shown on the protective device setting...
Guest 8 months ago in Other Gathering support