Collated Simulation Report

Could it be possible to select the reports wanted for export to PDF and then ProDesign includes them all into one documents with Titlepage and contents table and then the selected reports in order? I've received some electrical OM reports for revi...
Guest 9 months ago in Other Gathering support

Split Metered/Load Distribution Board

Customers would like the option to label two halves of the board differently e.g. DB1L and DB1P (L for lighting, P for power) so that the two halves of the board have their own identity. It will also require the ability to select the number of way...
Ayee Jarecki about 1 year ago in Components Gathering support

Changing Installation Method for an Armoured cable resets CPC configuration

When the Installation Method is changed the CPC configuration should be retained. The current functionality creates needless work.
Scott Dakin 8 months ago in Components Gathering support

Add devices from Protect to ProDesign

Add the devices from Protect into ProDesign so that I can correctly configure the source of supply. The list of available devices in ProDesign for LV and especially HV protection at source is rather limited.
Scott Dakin 10 months ago in Calculation Gathering support

415V/110V Supply for LV/LV Transformers

Add an option to take 415V single phase L-L supply from a board for the LV/LV transformers
Guest 12 months ago in Components Gathering support

Custom Reports

Customers would like to define the information they want instead of being dictated by us what appears on the standard reports. They also want their own company 'identity'. Allows customer to be more flexible in what they show on their reports. Con...
Ayee Jarecki about 1 year ago in Other Gathering support

Definition between existing and proposed systems

Currently, the program is great for new systems but not so good when retro fitting or upgrading electrical supplies. A way to distinguish between existing and new items would be great, circuit charts could just show 'existing' for circuits already...
Charles Proctor 6 months ago in Other Gathering support

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!

Trimble powernet is not user friendly like Trimble pro design. Frustrating!!!
Guest 7 months ago in Other Gathering support

Add adjustable settings to custom reports

The adjustable device settings dont currently show in custom reports. It would be useful if it were possible to add them, aswell as the time delays from adjustable RCDs. Adjustable RCD settings should also be shown on the protective device setting...
Guest 8 months ago in Other Gathering support

Add adjustable device settings to Display Results

I'd like the tripping curve of MCBs and ACB or MCCB adjustable pickup values to be options in the Display Results interface. Our site team wants them written on the canvas so i'm having to type them all out by hand. Yes, I agree it's a bit daft as...
Scott Dakin 8 months ago in Other Gathering support