Components

Split Metered/Load Distribution Board

Customers would like the option to label two halves of the board differently e.g. DB1L and DB1P (L for lighting, P for power) so that the two halves of the board have their own identity. It will also require the ability to select the number of way...
Ayee Jarecki about 1 year ago in Components Gathering support

Changing Installation Method for an Armoured cable resets CPC configuration

When the Installation Method is changed the CPC configuration should be retained. The current functionality creates needless work.
Scott Dakin 8 months ago in Components Gathering support

415V/110V Supply for LV/LV Transformers

Add an option to take 415V single phase L-L supply from a board for the LV/LV transformers
Guest 12 months ago in Components Gathering support

Set adjustable device pickup values for multiple devices simultaneously

Having to setup dozens of identical devices one-at-a-time instead of being able to do them all at the same time wastes unbelievable amounts of time. It's even worse when you have to iterate all of them several times, losing days to do what should ...
Scott Dakin 8 months ago in Components Gathering support

6.6kV rating applied to Merlin Gerin MV Ringmaster Range .

In Electricity North Wests area they have primary substation network operating at 6.6kV and a fault level of 250MVA. The Ringmaster range is rated to 21.9KA therefore compatible but it returns an error code for the Pscc exceeding fault capacity as...
Guest 20 days ago in Components Gathering support

Display Results in ProDesign

The Display Results feature is a melting pot of different ways of displaying information. While this makes it very configurable, when I try to use the same settings project wide it becomes a significant time sink as there is no global control that...
Scott Dakin 10 months ago in Components Gathering support

YNyn0 transformers in ProDesign

Provide the facility to work with transformers having various vector groups. My current application is a 415 / 690v transformer but I also require 110v CTE transformers.
Scott Dakin 10 months ago in Components Gathering support